278 research outputs found

    Scaling Relation for Occulter Manufacturing Errors

    Get PDF
    For directly imaging exoplanets, NASA is considering space mission designs that use an external occulter as the principal starlight suppression system. These occulter designs range in diameter from 16 to 40 meters and separation distance from 8,000 to 60,000 kilometers for telescopes with primary diameters of 0.5 to 4 meters. Occulter shapes are solutions to an optimization problem which seeks to maximize suppression in the shadow subject to constraints such as size, separation, and wavelengths. These designs are based on scalar diffraction theory and must be verified experimentally to demonstrate predicted on-orbit performance. Due to the large sizes and separations involved the experiment must be scaled to lab size. We are currently expanding the existing experimental test-bed at Princeton to enable scaling of occulters operating at flight Fresnel sizes. Here we examine the effect on suppression performance of edge defects and their scaling to test-bed size

    Review of high-contrast imaging systems for current and future ground- and space-based telescopes I. Coronagraph design methods and optical performance metrics

    Full text link
    The Optimal Optical Coronagraph (OOC) Workshop at the Lorentz Center in September 2017 in Leiden, the Netherlands gathered a diverse group of 25 researchers working on exoplanet instrumentation to stimulate the emergence and sharing of new ideas. In this first installment of a series of three papers summarizing the outcomes of the OOC workshop, we present an overview of design methods and optical performance metrics developed for coronagraph instruments. The design and optimization of coronagraphs for future telescopes has progressed rapidly over the past several years in the context of space mission studies for Exo-C, WFIRST, HabEx, and LUVOIR as well as ground-based telescopes. Design tools have been developed at several institutions to optimize a variety of coronagraph mask types. We aim to give a broad overview of the approaches used, examples of their utility, and provide the optimization tools to the community. Though it is clear that the basic function of coronagraphs is to suppress starlight while maintaining light from off-axis sources, our community lacks a general set of standard performance metrics that apply to both detecting and characterizing exoplanets. The attendees of the OOC workshop agreed that it would benefit our community to clearly define quantities for comparing the performance of coronagraph designs and systems. Therefore, we also present a set of metrics that may be applied to theoretical designs, testbeds, and deployed instruments. We show how these quantities may be used to easily relate the basic properties of the optical instrument to the detection significance of the given point source in the presence of realistic noise.Comment: To appear in Proceedings of the SPIE, vol. 1069

    Myalgic encephalomyelitis/chronic fatigue Syndrome (ME/CFS): Investigating care practices pointed out to disparities in diagnosis and treatment across European Union

    Get PDF
    ME/CFS is a chronic, complex, multisystem disease that often limits the health and functioning of the affected patients. Diagnosing patients with ME/CFS is a challenge, and many different case definitions exist and are used in clinical practice and research. Even after diagnosis, medical treatment is very challenging. Symptom relief and coping may affect how patients live with their disease and their quality of life. There is no consensus on which diagnostic criteria should be used and which treatment strategies can be recommended for patients. The purpose of the current project was to map the landscape of the Euromene countries in respect of national guidelines and recommendations for case definition, diagnosis and clinical approaches for ME/CFS patients. A 23 items questionnaire was sent out by email to the members of Euromene. The form contained questions on existing guidelines for case definitions, treatment/management of the disease, tests and questionnaires applied, and the prioritization of information for data sampling in research. We obtained information from 17 countries. Five countries reported having national guidelines for diagnosis, and five countries reported having guidelines for clinical approaches. For diagnostic purposes, the Fukuda criteria were most often recommended, and also the Canadian Consensus criteria, the International Consensus Criteria and the Oxford criteria were used. A mix of diagnostic criteria was applied within those countries having no guidelines. Many different questionnaires and tests were used for symptom registration and diagnostic investigation. For symptom relief, pain and anti-depressive medication were most often recommended. Cognitive Behavioral Therapy and Graded Exercise treatment were often recommended as disease management and rehabilitative/palliative strategies. The lack of consistency in recommendations across European countries urges the development of regulations, guidance and standards. The results of this study will contribute to the harmonization of diagnostic criteria and treatment for ME/CFS in Europe.publishedVersio

    Myalgic encephalomyelitis/chronic fatigue Syndrome (ME/CFS): Investigating care practices pointed out to disparities in diagnosis and treatment across European Union.

    Get PDF
    ME/CFS is a chronic, complex, multisystem disease that often limits the health and functioning of the affected patients. Diagnosing patients with ME/CFS is a challenge, and many different case definitions exist and are used in clinical practice and research. Even after diagnosis, medical treatment is very challenging. Symptom relief and coping may affect how patients live with their disease and their quality of life. There is no consensus on which diagnostic criteria should be used and which treatment strategies can be recommended for patients. The purpose of the current project was to map the landscape of the Euromene countries in respect of national guidelines and recommendations for case definition, diagnosis and clinical approaches for ME/CFS patients. A 23 items questionnaire was sent out by email to the members of Euromene. The form contained questions on existing guidelines for case definitions, treatment/management of the disease, tests and questionnaires applied, and the prioritization of information for data sampling in research. We obtained information from 17 countries. Five countries reported having national guidelines for diagnosis, and five countries reported having guidelines for clinical approaches. For diagnostic purposes, the Fukuda criteria were most often recommended, and also the Canadian Consensus criteria, the International Consensus Criteria and the Oxford criteria were used. A mix of diagnostic criteria was applied within those countries having no guidelines. Many different questionnaires and tests were used for symptom registration and diagnostic investigation. For symptom relief, pain and anti-depressive medication were most often recommended. Cognitive Behavioral Therapy and Graded Exercise treatment were often recommended as disease management and rehabilitative/palliative strategies. The lack of consistency in recommendations across European countries urges the development of regulations, guidance and standards. The results of this study will contribute to the harmonization of diagnostic criteria and treatment for ME/CFS in Europe

    DNA mediated chromatin pull-down for the study of chromatin replication

    Get PDF
    Chromatin replication involves duplicating DNA while maintaining epigenetic information. These processes are critical for genome stability and for preserving cell-type identity. Here we describe a simple experimental approach that allows chromatin to be captured and its content analysed after in vivo replication and labeling of DNA by cellular DNA polymerases. We show that this technique is highly specific and that proteins bound to the replicated DNA can be analyzed by both immunological techniques and large scale mass spectrometry. As proof of concept we have used this novel procedure to begin investigating the relationship between chromatin protein composition and the temporal programme of DNA replication in human cells. It is expected that this technique will become a widely used tool to address how chromatin proteins assemble onto newly replicated DNA after passage of a replication fork and how chromatin maturation is coupled to DNA synthesis

    Approximate Controllability for Linear Stochastic Differential Equations in Infinite Dimensions

    Full text link
    The objective of the paper is to investigate the approximate controllability property of a linear stochastic control system with values in a separable real Hilbert space. In a first step we prove the existence and uniqueness for the solution of the dual linear backward stochastic differential equation. This equation has the particularity that in addition to an unbounded operator acting on the Y-component of the solution there is still another one acting on the Z-component. With the help of this dual equation we then deduce the duality between approximate controllability and observability. Finally, under the assumption that the unbounded operator acting on the state process of the forward equation is an infinitesimal generator of an exponentially stable semigroup, we show that the generalized Hautus test provides a necessary condition for the approximate controllability. The paper generalizes former results by Buckdahn, Quincampoix and Tessitore (2006) and Goreac (2007) from the finite dimensional to the infinite dimensional case.Comment: 31 pages, submitted to AM

    Co-Package Technology Platform for Low-Power and Low-Cost Data Centers

    Get PDF
    We report recent advances in photonic–electronic integration developed in the European research project L3MATRIX. The aim of the project was to demonstrate the basic building blocks of a co-packaged optical system. Two-dimensional silicon photonics arrays with 64 modulators were fabricated. Novel modulation schemes based on slow light modulation were developed to assist in achieving an efficient performance of the module. Integration of DFB laser sources within each cell in the matrix was demonstrated as well using wafer bonding between the InP and SOI wafers. Improved semiconductor quantum dot MBE growth, characterization and gain stack designs were developed. Packaging of these 2D photonic arrays in a chiplet configuration was demonstrated using a vertical integration approach in which the optical interconnect matrix was flip-chip assembled on top of a CMOS mimic chip with 2D vertical fiber coupling. The optical chiplet was further assembled on a substrate to facilitate integration with the multi-chip module of the co-packaged system with a switch surrounded by several such optical chiplets. We summarize the features of the L3MATRIX co-package technology platform and its holistic toolbox of technologies to address the next generation of computing challenges
    • …
    corecore